Software Release note [ 4 ]

( 07.Jul.2014 update )

Ver.1.54B  [ 10.Jan.2014 ]

ADD MODELS

VRV  ( D3-NET connection only )
VRV4 for North-America RXYQ72T
VRV4 for ASEAN RWEYQ-PY17

Ver.1.54A  [ 11.Nov.2013 ]

ADD MODELS

VRV  ( D3-NET connection only )
VRV4W for DENV RWEYQ8-10T7Y1B

Ver.1.54  [ 11.Jul.2013 ]

ADD MODELS

VRV  ( D3-NET connection only )
VRV4(Q) for DENV RXYQQ8-20T7Y1B
VRV-X (for China) RUXYQ8AB
Home VRV (for China) RJQ10ABY

Modification

indoor unit

add BRC sensor temp. (remote controller thermo.)

Ver.1.53C  [ 09.Jan.2013 ]

Modification

Altherma LT

I had to modify the contents of several items that were wrong. ( Same content as the MEGA altherma )

VRV3 for US

Fixed a bug that Inverter_temp. Becomes abnormal when the value below 0 degrees Celsius.

Ver.1.53B  [ 04.Dec.2012 ]

ADD MODELS

VRV  ( D3-NET connection only )
Altherma LT HXY80-125A

Ver.1.53A  [ 01.Nov.2012 ]

Modification

WSHP Indoor unit

support WSHP Indoor unit.

Ver.1.53  [ 24.Sep.2012 ]

ADD MODELS

VRV  ( D3-NET connection only )
VRV4 HP RYYQ8-54T7Y1B, RXYQ8-54T7Y1B
indoor unit for
computer room
DFVP400-500M (for Thailand)

Modification

Small Inverter Chiller

change item name ( outdoor unit part )

Ver.1.52  [ 12.Jun.2012 ]

ADD MODELS

VRV  ( D3-NET connection only )
McQuay WSHP S2UWSQ36A (WSHP 3ton 4HP)
S2UWSQ48A (WSHP 4ton 5HP)

Ver.1.51C  [ 28.May.2012 ]

ADD MODELS

VRV  ( D3-NET connection only )
Total Solution VRV
( Mega Altherma )
HXHD125A7V1B

Ver.1.51B  [ 16.Apl.2012 ]

Modification

VRV3 for China : The wrong place was corrected.

  1. Outdoor unit current
  2. Subcooling_heat_exchanger_gas_temp., Subcooling_heat_exchanger_liquid_temp.

ADD MODELS

VRV  ( D3-NET connection only )
Small Inverter Chiller
( Mega Altherma )
EWAQ016-064BAW

Ver.1.51A  [ 16.Mar.2012 ]

Modification

VRV3 for China : Inverter fin tmp.

Fault in case inverter fin temperature is minus is corrected.

add model VRV3W (Water) other type

VRV3W(Water) : RWEYQ8-30P - The 2nd version model of the VRV3W addition

Ver.1.51  [ 22.Feb.2012 ]

ADD MODELS

VRV  ( D3-NET connection only )
VRV3 for China RHXYQ8-48SY1, RHXYQ10-42SAY1


Modification

Supposing it enlarges a screen using a high resolution monitor, an error will occur.

When breadth tended to use a high resolution monitor (FullHD 1920x1080 grade) of 1800 pixels or more and tended to display an operation display screen etc. greatly, the fault which carries out an abnormal end was corrected.

Ver.1.50C  [ 12.Dec.2011 ]

ADD MODELS

VRV  ( D3-NET connection only )
VRV for DENV RXYRQ8-18P7W1B



Ver.1.50A  [ 22.Mar.2011 ]

Modification

Altherma Indoor Unit revised

1) Data name modified

Data name : Symbol ==> Parameter name

ex. TwR ==> Return water temperature, HTh1 ==> Remocon ambient temperature

2) Display unit for pump revolution speed

Changed from rps(revolution per second) to rpm(revolution per minute)

3) 4 parameter items added

Add item :
 SWF(flow swith)
 ST2L(external room thermostat cooling)
 SV32(space heating/cooling 2way valve)
 SVE(cooling solenoid)

4) Conversion table for Tsch(R134a liquid temperature), HTdi(Discharge temperature) temp. has been corrected

Doubled (x2) from original value

5) Scale for EV and Pump revolution value modified

Pump revolutions : 4000
EV_L : 2000
EV_H : 1000
EV_C : 2000


Ver.1.50  [ 15.Dec.2010 ]

Modification

1. add Detail data list at Opration Data display

add new menu Opration Data Display[Detail]. The screen where the item (period) displayed in the graph was displayed by the list was added. As a result, it comes to be able to confirm the change of the value not understood easily in the graph directly by the numerical value.

 

The data that can be displayed is the same as the graph (the analogue 8 points, digital 8 points, and 16 points in total). The period is a period displayed in the graph. (After changing the graph, changing the item and the period displays it again. )

2. Screen size adjustment for Windows-7, Vista, Xp

It was partly modified to turn Windows 7, Vista, Xp.

The matter that a part hid and which wasn't indicated was modified by "Display Operation data" that the size of window can be changed, the indication of the "Customer data Selection" screen by the default of Windows 7, Vista, Xp.

Phenomenon :

A standard window frame is wider than the former mode (the classical mode) with Windows 7, Vista. Therefore, an indication area became small, and a part couldn't be indicated any more. And, a part under window partly broke off because top title part was wide even with Windows Xp.

 Windows Vista

 Windows Xp

 Windows 2000

It wasn't understood because development and a test environment were confirmation in the classical mode of Windows2000 and Windows95. Indication was checked with Windows2000.
It was found out this time in the movement confirmation of Windows 7.

Correspondence :

It was changed to compute arrangement in consideration of the frame of window.

After it copes with it.

 Windows Vista

 Windows Xp

3. Change Installer

change software instller.
Visual Basic V5.0 Installer -> Visual Studio Installer (Visual studio 6.0 base)

4. The screen print button of the driving data display is changed.

The screen print button is changed (Change from the character to the icon).
The confirmation of "Print Screen Image. OK?" is added the print soon with the screen print button once. It was prevented from being printed when pushing by mistake.

ADD MODELS

VRV  ( D3-NET connection only )
VRV for North America in-unit FXTQ
out-unit RZQ18/24PVJU
Altherma Altherma HT -
Mega Altherma EMRQ8-16AAY1,
EKHVMRD50-80AAV1, EKHVMYD50-80AAV1
ZEAS for Low Temp. New Firm Ver. LRLEQ5-20A(Y1), LRMEQ5-8A(Y1)



-> before Ver.1.18A